Language:
IBM Proprinter Speed: 240cps Draft, 80cps Letter-Quality Graphics: 60, 180, 360dpi No. of Pins: 24 |
Internal Fonts
Typeface Quality Heights Pitches Styles Weights
Normal Draft sing, dbl 10, 12, 17 normal normal, dbl strike
Courier LQ sing, dbl 10, 17 normal normal, emphasized
Prestige Elite LQ sing, dbl 12 normal normal, emphasized
Italic is not available internally.
Tractor Feed: Push
feed
Optional Feeders: Optional cut-sheet feeder
Manual Feeding
1. Set the paper release lever toward the rear of the printer and set the form-thickness lever to the correct position for the type of forms you are using.
2. Slide the paper or
envelope into the front opening, aligning the left edge of the
paper with the cut-form guide. Slide the paper in until it stops.
Unless you keep the paper against the cut-form guide, the printer
does not sense the paper. (The cut-form guide is adjustable,
allowing you to vary the left margin)
3. Turn the paper advance knob to move the paper until the printhead is at the point where you want the printing to start.
4. Press the On-Line key and start your printing routine.
Printer Function Settings (see page 3-35 in IBM Proprinter X-24E Guide to Operations):
Setting | Function | ON | OFF |
1 | Alarm | Disable Alarm | Enable Alarm |
2 | Sheet Feeder | Enable Sheet Feeder | Disable Sheet Feeder |
3 | Line Length (XL-24E only) | Select 8 inch print line | Select 13 inch print line |
4 | Alternate Graphic Mode | Use alternate graphics support | Do not use alternate graphics support |
5 | Reserved | Reserved | Reserved |
6 | USA/Multilingual font | Initialize download fonts as multilingual | Initialize download fonts as USA |
7 | Character Set | Select Character set 2 | Select character set 1 |
8 | Zero Slash | Select slashed zero | Select normal zero |
9 | Form length | Select 12 inch forms | Select 11 inch forms |
10 | Automatic Line Feed | Auto line feed after carriage return | Carriage return only |
11 | Automatic carriage return | No carriage return after vertical movement | Automatic carriage return after vertical movement |
Parallel
Availability: Standard
Connection: Centronics Female
Activation: Automatic